Liquid-to-Air Cooling
Uses ambient air to cool your application. Heated process fluid is pumped through the unit's fan-cooled heat exchanger and returned to the process.
Liquid-to-Liquid Cooling
Uses your facility's water, pumped through the unit, to remove heat from your application without risk of contamination. Heat removal capacity is dependent on the facility water temperature.
FlOW-THROUGH STYLE COOLERS
Extend the temperature range of non-refrigerated circulators to below ambient and boost the cooling capacity of refrigerated circulators. These coolers also offer an extremely economic alternative to tap water cooling of heated circulating baths when rapid cool-downs or operation at or near ambient is needed.
4 Products
More Options Available

Model 3370 Liquid-to-Air Cooler, 1/3 HP Turbine Pump
More Options Available

Model 3370 Liquid-to-Air Cooler, 1/3 HP Positive Displacement Pump
More Options Available

Model 4100 Liquid-to-Liquid Cooler
More Options Available

Flow Through Cooler
Pump Type
Turbine
Positive Displacement
Turbine
N/A
Working Temperature Range °C
Ambient +5° to 70°C
Ambient +5° to 70°C
Facility water +10° to 60°
-25° to +40°
Part Number for 60 Hz Model
3370TBA11B
3370P9A11B
4150T21A130D
F25N0A101B
Part Number for 50 Hz Model
3370TBA12E
3370P9A12E
4150T21A130E
F25N0A102E
Electrical Requirements (VAC/Hz/Ph/A) (60Hz)
120/60/1/5.5
120/60/1/5.5
208-230/60/1/3
120/60/1/5
Electrical Requirements (VAC/Hz/Ph/A) (50Hz)
240/50/1/3
240/50/1/3
240/50/1/3
240/50/1/2.5
More Options Available
Pump Type
Turbine
Working Temperature Range °C
Ambient +5° to 70°C
Part Number for 60 Hz Model
3370TBA11B
Part Number for 50 Hz Model
3370TBA12E
Electrical Requirements (VAC/Hz/Ph/A) (60Hz)
120/60/1/5.5
Electrical Requirements (VAC/Hz/Ph/A) (50Hz)
240/50/1/3
More Options Available
Pump Type
Positive Displacement
Working Temperature Range °C
Ambient +5° to 70°C
Part Number for 60 Hz Model
3370P9A11B
Part Number for 50 Hz Model
3370P9A12E
Electrical Requirements (VAC/Hz/Ph/A) (60Hz)
120/60/1/5.5
Electrical Requirements (VAC/Hz/Ph/A) (50Hz)
240/50/1/3
More Options Available
Pump Type
Turbine
Working Temperature Range °C
Facility water +10° to 60°
Part Number for 60 Hz Model
4150T21A130D
Part Number for 50 Hz Model
4150T21A130E
Electrical Requirements (VAC/Hz/Ph/A) (60Hz)
208-230/60/1/3
Electrical Requirements (VAC/Hz/Ph/A) (50Hz)
240/50/1/3
More Options Available
Pump Type
N/A
Working Temperature Range °C
-25° to +40°
Part Number for 60 Hz Model
F25N0A101B
Part Number for 50 Hz Model
F25N0A102E
Electrical Requirements (VAC/Hz/Ph/A) (60Hz)
120/60/1/5
Electrical Requirements (VAC/Hz/Ph/A) (50Hz)
240/50/1/2.5